Trade Tools

Gas Rate Calculator

Meter test, kW gross and net.

in testingplumbersiteandroid

Time the gas meter with the built-in stopwatch and get the appliance heat input in kW gross and net, metric or imperial meter, compared with the data plate.

How it works, a worked example and screenshots ↓

Pay once, no subscription, no ads.

Platform
Android
Version
1.0
Source
Private source · Studio product
Price
£3.99

Runs on your phone, no internet needed. When it is on Google Play, updates will come through Play next time you're online.

Want to know when it launches? Email forestforge.dev@gmail.com.

Gas Rate Calculator artwork
Gas Rate Calculator app screen
Screenshot from the Android app

What it does

Gas Rate Calculator times the meter with only the appliance running at full rate and works out the heat input in kW gross and net, and how far it is from the data plate. It has a built-in stopwatch and works with metric and imperial meters.

Who it's for

Registered gas engineers commissioning or servicing boilers, fires and cookers.

How to use it

  1. 1Turn off every other appliance and run the one under test at full rate.
  2. 2Choose a metric or imperial meter and the volume you will time.
  3. 3Start the stopwatch as the dial passes a mark and stop it when that volume has passed, or type the time.
  4. 4Enter the calorific value and the data plate input, gross or net.
  5. 5Read the heat input and the difference from the data plate.

Inputs and outputs

You enter

  • Meter type: metric (m³) or imperial test dial (ft³)
  • Volume passed and time in seconds (stopwatch built in)
  • Calorific value (MJ/m³) from the gas bill
  • Data plate input (kW), gross or net

You get

  • Gas flow in m³/h
  • Heat input in kW gross, kW net and BTU/h
  • Difference from the data plate as a percentage
  • How long the test should take at the data plate rate

Worked example

A combi boiler on a metric meter

Given

  • 0.025 m³ passed in 60 s
  • CV 39.5 MJ/m³
  • Data plate 16.5 kW gross

Working

  1. m³/h = 0.025 × 3600 ÷ 60 = 1.500
  2. kW gross = 1.500 × 39.5 ÷ 3.6 = 16.46
  3. kW net = 16.46 ÷ 1.11 = 14.83

Result

16.46 kW gross (14.83 net), −0.3 % against the data plate.

An example only: your job will differ, so check the figures against the working in the app.

Features

  • Built-in stopwatch for timing the meter
  • Metric and imperial meters
  • Gross and net kW, BTU/h and the difference from the data plate
  • Natural gas, with the calorific value you enter
  • Formulas and working shown, with a clear guide-only note
  • Copy, print to PDF, export JSON or open the result in the Plumber Suite
  • Works offline, no account, no ads

Screenshots

The tool with its starting values
The tool with its starting values
Formulas, working and the results panel
Formulas, working and the results panel

Guide only

Natural gas with the calorific value you enter. Gas work is for registered gas engineers only. A guide only: check against the manufacturer's instructions. The app shows its formulas and working so you can check every figure. It is not a substitute for your own judgement, training or the published standards.

More plumber tools

All plumber tools