Radiator BTU Calculator

Heat loss, BTU, radiator size.

in testingplumbersiteandroid

Work out a room's heat loss from its walls, windows, ceiling, floor and air changes, in watts and BTU/h, then the catalogue radiator size you need for a boiler or heat pump flow temperature.

How it works, a worked example and screenshots ↓

Pay once, no subscription, no ads.

Platform
Android
Version
1.0
Source
Private source · Studio product
Price
£3.99

Runs on your phone, no internet needed. When it is on Google Play, updates will come through Play next time you're online.

Want to know when it launches? Email forestforge.dev@gmail.com.

Radiator BTU Calculator artwork
Radiator BTU Calculator app screen
Screenshot from the Android app

What it does

Radiator BTU Calculator works out a room's heat loss from its walls, windows, ceiling, floor and air changes, in watts and BTU/h, then the catalogue radiator output you need at your flow and return temperatures, for a boiler or a heat pump.

Who it's for

Heating engineers and plumbers sizing radiators, and anyone swapping a boiler for a heat pump who needs to know if the radiators are big enough.

How to use it

  1. 1Pick the room type, which sets the inside temperature and air changes.
  2. 2Enter the room size, the external wall length and the window and door area.
  3. 3Choose the wall, window, ceiling and floor construction.
  4. 4Set the outside design temperature, the margin and the flow and return temperatures.
  5. 5Read the room loss and the ΔT50 catalogue output you need.

Inputs and outputs

You enter

  • Room type, inside and outside temperatures, air changes per hour
  • Length, width and height (m)
  • External wall length and window and door area
  • Wall, window, ceiling and floor construction (U-values)
  • Margin and flow / return temperatures

You get

  • Room heat loss in watts and BTU/h
  • Fabric and ventilation losses shown separately
  • Catalogue (ΔT50) radiator output needed at your mean water temperature

Worked example

A living room on a boiler

Given

  • Living room 4 × 3.5 × 2.4 m, 21 °C inside, −3 °C outside, 1.5 air changes
  • 4 m external wall, unfilled cavity; 1.5 m² of pre-2002 double glazing
  • Heated room above; suspended timber floor, uninsulated; 10 % margin
  • Flow 75 °C, return 65 °C

Working

  1. ΔT = 21 − (−3) = 24 K
  2. Ventilation = 0.33 × 1.5 × 33.6 m³ × 24 = 399 W
  3. Walls 292 W + windows 101 W + floor 235 W + air 399 W = 1,027 W
  4. + 10 % margin = 1,129 W (3,854 BTU/h)
  5. Mean water 70 °C, 49 K above the room: output × (49 ÷ 50)^1.3 = × 0.974
  6. ΔT50 needed = 1,129 ÷ 0.974 = 1,160 W

Result

You need a radiator rated about 1,160 W (3,956 BTU/h) at ΔT50.

An example only: your job will differ, so check the figures against the working in the app.

Features

  • Room heat loss in watts and BTU/h, fabric and air shown
  • Typical U-values for older and newer houses
  • Catalogue ΔT50 output corrected for boiler or heat pump temperatures
  • Margin option for exposed rooms
  • Formulas and working shown, with a clear guide-only note
  • Copy, print to PDF, export JSON or open the result in the Plumber Suite
  • Works offline, no account, no ads

Screenshots

The tool with its starting values
The tool with its starting values
Formulas, working and the results panel
Formulas, working and the results panel

Guide only

Typical UK U-values and air changes, not a survey. A guide only: check against the regulations and the radiator maker's data. The app shows its formulas and working so you can check every figure. It is not a substitute for your own judgement, training or the published standards.