Trade Tools

Pipe Sizing & Flow

Velocity, friction loss, size.

in testingplumbersiteandroid

Size copper and MDPE pipe from a water flow or a heating load: velocity, Hazen–Williams friction loss over the run and the smallest copper size that stays quiet and inside the pressure available.

How it works, a worked example and screenshots ↓

Pay once, no subscription, no ads.

Platform
Android
Version
1.0
Source
Private source · Studio product
Price
£3.99

Runs on your phone, no internet needed. When it is on Google Play, updates will come through Play next time you're online.

Want to know when it launches? Email forestforge.dev@gmail.com.

Pipe Sizing & Flow artwork
Pipe Sizing & Flow app screen
Screenshot from the Android app

What it does

Pipe Sizing & Flow works out the velocity and friction loss for copper and MDPE pipe from a water flow or a heating load, and picks the smallest copper size that stays quiet and keeps the loss inside the pressure you have.

Who it's for

Plumbers and heating engineers sizing hot and cold supplies, heating flow and returns, and new mains.

How to use it

  1. 1Choose Water flow or Heating load.
  2. 2Enter the flow rate (or the heat load and temperature drop).
  3. 3Enter the pipe length, a fittings allowance and the pressure available for this run.
  4. 4Pick the maximum velocity: 1.0 m/s quiet, 1.5 usual or 2.0 BS EN 806 maximum.
  5. 5Read the smallest copper size that passes, with every size shown.

Inputs and outputs

You enter

  • Flow rate (l/min), or heating load (kW) and ΔT
  • Pipe length (m) and fittings allowance (%)
  • Pressure available for this run (bar)
  • Maximum velocity

You get

  • Smallest copper size that passes
  • Velocity (m/s) and friction loss (m head and bar) for each copper and MDPE size
  • Pass or fail for velocity and pressure on every size

Worked example

A bath tap on a 20 m run

Given

  • 18 l/min, 20 m of pipe, 30 % for fittings
  • 1.5 bar available (15.3 m head), 1.5 m/s maximum

Working

  1. Q = 18 ÷ 60 000 = 0.000300 m³/s
  2. 15 mm: 2.07 m/s, too fast
  3. 22 mm: 0.94 m/s, friction loss 1.58 m (Hazen–Williams)
  4. 1.58 m is well inside 15.3 m head

Result

22 mm copper: 0.94 m/s and 1.58 m loss (0.155 bar).

An example only: your job will differ, so check the figures against the working in the app.

Features

  • Velocity and friction loss for copper and MDPE
  • From a water flow or a heating load
  • Smallest quiet size picked, every size compared
  • Hazen–Williams working shown in full
  • Formulas and working shown, with a clear guide-only note
  • Copy, print to PDF, export JSON or open the result in the Plumber Suite
  • Works offline, no account, no ads

Screenshots

The tool with its starting values
The tool with its starting values
Formulas, working and the results panel
Formulas, working and the results panel

Guide only

Hazen–Williams for cold water. A guide only: check against BS EN 806, the regulations and the manufacturer's data. The app shows its formulas and working so you can check every figure. It is not a substitute for your own judgement, training or the published standards.