Trade Tools

Unvented Cylinder Checklist

G3 checks, D2 sizing, record.

in testingplumbersiteandroid

An on-site commissioning checklist for unvented hot water cylinders: the G3 checks, pressures and temperatures, D2 discharge pipe sizing, and a printable certificate-style record.

How it works, a worked example and screenshots ↓

Pay once, no subscription, no ads.

Platform
Android
Version
1.0
Source
Private source · Studio product
Price
£3.99

Runs on your phone, no internet needed. When it is on Google Play, updates will come through Play next time you're online.

Want to know when it launches? Email forestforge.dev@gmail.com.

Unvented Cylinder Checklist artwork
Unvented Cylinder Checklist app screen
Screenshot from the Android app

What it does

Unvented Cylinder Checklist takes you through the G3 commissioning checks, records the pressures, valve settings and temperatures, sizes the D2 discharge pipe from its length and bends, and prints a certificate-style record for the customer.

Who it's for

G3-qualified plumbers and heating engineers installing, commissioning or servicing unvented hot water cylinders.

How to use it

  1. 1Enter the customer, address, cylinder, serial number and your G3 card number.
  2. 2Record the static and dynamic pressure, flow, PRV, vessel and valve settings and temperatures.
  3. 3Tick through the 16 commissioning checks.
  4. 4Enter the D2 valve outlet size, straight length and bends.
  5. 5Print the record and leave it with the instructions.

Inputs and outputs

You enter

  • Installation details and G3 card number
  • Static and dynamic pressure, flow at the outlet
  • PRV setting, vessel pre-charge, expansion and T&P valve settings
  • Thermostat setting and hottest outlet temperature
  • D2: valve outlet size, straight length, number of bends

You get

  • Checks done out of 16
  • D2 size and its equivalent length against the maximum
  • A printable commissioning record

Worked example

A 210 litre cylinder, 4 m of D2 with three bends

Given

  • 15 mm valve outlet, 22 mm D2
  • 4 m straight with 3 elbows

Working

  1. Each 22 mm bend counts as 0.8 m
  2. Equivalent length = 4 + 3 × 0.8 = 6.4 m
  3. Maximum for 22 mm from a 15 mm valve = 9 m

Result

D2 22 mm is OK: 6.4 m of 9 m.

An example only: your job will differ, so check the figures against the working in the app.

Features

  • All 16 G3 commissioning checks in one list
  • Pressures, valve settings and temperatures recorded
  • D2 discharge sized from length and bends
  • Certificate-style record to print
  • Formulas and working shown, with a clear guide-only note
  • Copy, print to PDF, export JSON or open the result in the Plumber Suite
  • Works offline, no account, no ads

Screenshots

The checklist with the D2 result at the top
The checklist with the D2 result at the top
Installation details and readings
Installation details and readings

Guide only

A record to support the cylinder maker's commissioning checklist, not a replacement. A guide only: check against Approved Document G and the manufacturer's instructions. The app shows its formulas and working so you can check every figure. It is not a substitute for your own judgement, training or the published standards.

More plumber tools

All plumber tools